shaping the future
CD-116 Field Digital Switchboard
Electrical Specifications |
|
|
|
Power Supply |
|
|
90 to 132 VAC (47 – 63 Hz) or |
|
|
|
180 to 264 VAC (47 - 63 Hz) or |
|
|
|
21 to 28 VDC |
Consumption |
|
|
39 / 47 / 55 / 63 W typical (16 / 32 / 48 / 64 multifunctional interfaces) |
|
|
|
|
Multifunctional Interfaces |
|
|
|
Lightning Protection |
|
|
ITU-T K.11 & K.21 (6 kV) |
Loop resistance (line side) |
|
|
|
CBS mode |
|
|
5000 Ω @ 7 mA (off-hook/on-hook detection and pulse dialling) |
CB mode |
|
|
1300 Ω @ 20 mA |
Closing voltage (exchange side) |
|
|
|
CBS mode |
|
|
4 V @ 7 mA |
CB mode |
|
|
5V @ 20 mA |
Ring Current Generator |
|
|
60 Vrms 20 Hz ±10%, 2 REN |
Ring Current Detector |
|
|
35 Vrms, 10 – 40Hz |
|
|
|
|
Radio Interfaces |
|
|
|
PTT |
|
|
100 mA, 40 Ω |
Squelch |
|
|
10 – 60 V, 2.2 kΩ |
|
|
|
|
E&M Interfaces |
|
|
0 or -48 V signalling |
|
|
|
|
All analogue interfaces |
|
|
|
Insertion loss |
|
|
± 1 dB @ 300 – 3400 Hz |
Return loss |
|
|
10 dB @ 600 Ω, 300 – 3400 Hz |
Crosstalk |
|
|
-65 dB @ 300 – 3400 Hz |
Group delay distortion |
|
|
1.5 ms @ 300 – 3400 Hz |
Idle noise |
|
|
-65 dBm0p |
Intermodulation distortion |
|
|
-40 dB @ 300 – 3400 Hz |
|
|
|
|
Environmental Specifications |
|
|
MIL-STD-810F |
Operating temperature |
|
|
-25 to +70 ºC |
Storage temperature |
|
|
-40 to +75 ºC |
Humidity |
|
|
0 to 95 % |
Watertightness |
|
|
Method 512.4 |
Shock |
|
|
Method 516.5 |
Vibration |
|
|
Method 514.5 |
|
|
|
|
Physical Specifications |
|
|
|
Dimensions (W x D x H) |
|
|
340 x 450 x 193 mm |
Weight |
|
|
13.9 / 14.5 / 15.1 Kg typical (16 / 32 / 48 multifunctional interfaces) |
Case color |
|
|
olive green, RAL 6014
|
Back to Switchboards & Telephones