CD-116 Field Digital Switchboard

The Field Digital Switchboard CD-116 is a state-of-the art digital switching unit for military field tactical networks requiring integration of voice and data communications.
With the CD-116, a wide range of equipment may be integrated  in a field communication system:

  • Analogue telephones (Local Battery and Common Battery)

  • Digital terminals (voice and data) and computers

  • Radio equipment (Combat Net Radios and others)

  • Other switchboards, even old magneto type ones

  • Public Networks (analogue and digital)



A highly compact solution provides complete system accessibility through front and rear connectors and binding posts.
The Operator Terminal is integrated in the front panel and includes an alphanumeric VF display, a keyboard and the operator handset/headset connector.

The CD-116 fulfils all operational and mechanical requirements for field environment operation. Its small size and low weight, together with its inherent properties for communication readiness, makes it particularly suitable when mobility, reliability and maintainability are required.

Main Features

Interfaces and Capacity

  • Up to 60 analogue interfaces for CB, CBS and LB telephones

  • Up to 4 Radio Interfaces (voice, PTT and squelch)  

  • Up to 4 E&M Interfaces (4 or 6 wires)

  • Up to 12 CO interfaces for legacy PBX or analogue PSTN

  • Up to 3 PRI ISDN interfaces G.703 or Eurocom A/B or C

  • Up to 6 BRI ISDN Interfaces

 

Functionalities

Automatic Call Establishment:

  • CB or CBS telephones with Pulse or DTMF dialing
  • Radio and LB telephones with DTMF dialing


Operator Assisted Calls:

  • CB, CBS and LB telephones and radios

Hot Line (fixed destination)

Call Parking

Consultation and Call Swapping

Call Waiting (Camp on), Call Hold and Call Transfer

Call Forwarding

Three Party and Extended Conference Call

Call Priority and Pre-emption

EURO ISDN Services

Built-in self test (BITE) for easy and fast diagnostics

Integrated AC and DC input power supply with automatic switching to battery back up, in case of AC mains failure

CD-116 Field Digital Switchboard

Technical information

Electrical Specifications      
Power Supply     90 to 132 VAC (47 – 63 Hz) or
      180 to 264 VAC (47 - 63 Hz) or
      21 to 28 VDC
Consumption     39, 47 or 55 W for 16, 32 or 48 multifunctional interfaces, typical
       
Multifunctional Interfaces      
Lightning Protection     ITU-T K.11 & K.21 (6 kV)
Loop resistance (line side)      
CBS mode     5.000 Ω @ 7 mA (off-hook/on-hook detection and pulse dialing)
CB mode     1.300 Ω @ 20 mA
Closing voltage (exchange side)      
CBS mode     4 V @ 7 mA
CB mode     5V @ 20 mA
       
Ring Current Generator     60 Vrms 20 Hz ±10%, 2 REN
Ring Current Detector     35 Vrms, 10 – 40Hz
       
Radio Interfaces      
PTT     100 mA, 40 Ω
Squelch     10 – 60 V, 2,2 kΩ
       
E&M Interfaces     0 or -48 V signaling
       
All analogue interfaces      
Insertion loss     ± 1 dB @ 300 – 3400 Hz
Return loss     10 dB @ 600 Ω, 300 – 3400 Hz
Crosstalk     -65 dB @ 300 – 3400 Hz
Group delay distortion     1,5 ms @ 300 – 3400 Hz
Idle noise     -65 dBm0p
Intermodulation distortion     -40 dB @ 300 – 3400 Hz
       
Environmental Specifications
    MIL-STD-810F
Operating temperature     -25 to +70 ºC
Storage temperature     -40 to +75 ºC
Humidity     0 to 95 %
Waterproof     Method 512.4
Shock     Method 516.5
Vibration     Method 514.5
       
Physical Specifications      
Dimensions (W x D x H)     340 x 450 x 193 mm
Weight     13,9 – 14,5 – 15,1 Kg for 16 – 32 – 48 multifunctional interfaces, typical
Case Color     Olive green, RAL 6014

 

 

 

For more information, please download our Field Communications catalogue.